to retrieve the universally unique ID (UUID) for the indicated disk on the node shown using the indicated command in order to check for sharedness across nodes determined that the disk did not have a UUID. Sharedness could not be checked for this device.
- Action: To check sharedness for the indicated device, assigned it a UUID using the commands specific to the platform and retry the sharedness check. Alternatively, select a different device with a UUID for shared access and verify sharedness for that disk.
-
PRVG-2078 : Execution of command "/sbin/udevadm info -n /dev/sdb1 -q all" on node "12c-rac01" for disk "/dev/sdb1" showed there was no UUID in the disk label.
- Cause: An attempt to retrieve the universally unique ID (UUID) for the indicated disk on the node shown using the indicated command in order to check for sharedness across nodes determined that the disk did not have a UUID. Sharedness could not be checked for this device.
- Action: To check sharedness for the indicated device, assigned it a UUID using the commands specific to the platform and retry the sharedness check. Alternatively, select a different device with a UUID for shared access and verify sharedness for that disk.
-
PRVG-0805 : Signature for storage path "/dev/oracleasm/disks/OCR" could not be determined on node "12c-rac01".
- Cause: An error occurred while attempting to determine the storage signature of the indicated path. Accompanying messages provide further details.
- Action: Resolve the issues described in any accompanying messages and retry.
- )
报错大致意思为,检查磁盘时,运行如下命令<
/usr/ |